Configuration 431
Option 46 EVFU Control with no PI
150B/L150B
Option
Number Display Configuration
Description
.0 46.0 Disable EVFU control with no PI and control codes: SO for double
wide, SI for mode 5 print, and BS (OEH, OFH, and 08H) for
nondestructive backspace. (default) Configuration Operation 42.x
is ignored but PI EVFU remains functional (61.1 set).
.1 46.1 Enable EVFU control with no PI and control codes: SO for alternate
font, SI for deselect alternate font, and BS (OEH, OFH, and 08H)
for elongated print.
.2 46.2 Same as 46.1 setting with the exception of the interpretation of the
ESC code [1BH]. ESC cannot be used to initiate an escape
sequence; instead use SOH code [01H] as an alternative.All control
codes 10H 1FH, including DC2, DC4 and CAN, can be used as
EVFU channel commands.
.3 46.3 Same as 46.0 except BS (08H) is used to turn oneline vertical
elongated ON.
NOTE: 46.1 is effected by Control Code 42 and Control Codes 10H 1FH
can be used as EVFU control commands (except for ESC code
[1BH] that is part of an escape sequence and codes DC 2 [12H],
DC4 [14H], and CAN [18H].