Option 46 — EVFU Control with no PI

150B/L150B

Option Display Number

.0 46.0

Configuration

Description

Disable EVFU control with no PI and control codes: SO for double wide, SI for mode 5 print, and BS (OEH, OFH, and 08H) for non–destructive backspace. (default) Configuration Operation 42.x is ignored but PI EVFU remains functional (61.1 set).

.1

46.1

Enable EVFU control with no PI and control codes: SO for alternate

 

 

font, SI for deselect alternate font, and BS (OEH, OFH, and 08H)

 

 

for elongated print.

 

 

 

.2

46.2

Same as 46.1 setting with the exception of the interpretation of the

 

 

ESC code [1BH]. ESC cannot be used to initiate an escape

 

 

sequence; instead use SOH code [01H] as an alternative.All control

 

 

codes 10H – 1FH, including DC2, DC4 and CAN, can be used as

 

 

EVFU channel commands.

 

 

 

.3

46.3

Same as 46.0 except BS (08H) is used to turn one–line vertical

 

 

elongated ON.

 

 

 

NOTE: 46.1 is effected by Control Code 42 and Control Codes 10H – 1FH can be used as EVFU control commands (except for ESC code [1BH] that is part of an escape sequence and codes DC 2 [12H], DC4 [14H], and CAN [18H].

Configuration

4–31

Page 83
Image 83
Printronix MVP Series user manual Option 46 Evfu Control with no PI