Option 25 — Binary Count Slew
MVP/L150
Option | Display | Configuration |
Number |
| Description |
|
|
|
.0 | 25.0 | With Control Code 10H (binary count of 0) causes one line slew, |
|
| 11H (binary count of 1) causes a two line slew, and each code incre- |
|
| ments by one up to Control Code 1FH (binary count of 15) which |
|
| causes a 16 line slew. |
| 25.1 | With set, the entire sequence is shifted by one so that Control Code |
.1 | ||
|
| 10H (binary count of 0) causes a 16 line slew instead of one, 11H |
|
| causes a one line slew, and Control Code 1FH (binary count of 15) |
|
| causes a 15 line slew. |
|
|
|
NOTE: If Paper Instruction (PI) is enabled by configuration option 61.1, option 25 enables the user to shift the values for the line slew control codes by one. Note that a single PI (hex 00) command will slew a blank line.
150B/L150B
Option | Display | Configuration | |
Number |
| Description | |
|
|
| |
.0 | 25.0 | Slew 1 to 16 lines for line terminators PI (hex 00) thru PI (hex 0F). | |
.1 | 25.1 | Slew 1 to 15 lines for line terminators PI (hex 00) thru PI (hex 0F). | |
|
| PI (hex 00) and PI (hex 01). | |
|
|
|
NOTE: Note that a single PI (hex00) command will slew a blank line. The distance between each
Configuration |