Table B–1. Fault Code Chart

Check Indicator

Fault Code

Fault Description

Corrective Action

Flashing

Flashing

011

012

No paper

Forms thickness lever open; shuttle assembly cover off or out of place.

Load paper

Close lever; replace or reseat shuttle cover.

Flashing

Flashing

Steady

014

015

030

031

032

040

033

041

050

051

Shuttle jam

Shuttle not up to speed

Printer memory: checksum or pattern check. These are ”soft” faults.

Remove jammed paper or straighten ribbon.

Remove any jammed paper; straighten ribbon; or check that forms thickness lever is in cor- rect position.

None, but can be bypassed. Keep a log of these codes and when they occur for your field service representative.

Steady

Steady

All switch indicators On or Off

060

061

None

Power supply: +30/+12 voltage failure

Power supply: –16/–12 voltage failure

Data processor malfunction

None. Call an authorized service representative.

None. Call an authorized service representative.

None. Call an authorized service representative.

Clear Check Condition

After all faults are corrected:

1.Press CHK to clear the fault condition (CHK indicator will go out).

2.If applicable, press RDY to place the printer on–line.