Table B–1. Fault Code Chart
Check Indicator
Fault Code
Fault Description
Corrective Action
Flashing
Flashing
011
012
No paper
Forms thickness lever open; shuttle assembly cover off or out of place.
Load paper
Close lever; replace or reseat shuttle cover.
Flashing
Flashing
Steady
014
015
030
031
032
040
033
041
050
051
Shuttle jam
Shuttle not up to speed
Printer memory: checksum or pattern check. These are ”soft” faults.
Remove jammed paper or straighten ribbon.
Remove any jammed paper; straighten ribbon; or check that forms thickness lever is in cor- rect position.
None, but can be bypassed. Keep a log of these codes and when they occur for your field service representative.
Steady
Steady
All switch indicators On or Off
060
061
None
Power supply: +30/+12 voltage failure
Power supply:
Data processor malfunction
None. Call an authorized service representative.
None. Call an authorized service representative.
None. Call an authorized service representative.
Clear Check Condition
After all faults are corrected:
1.Press CHK to clear the fault condition (CHK indicator will go out).
2.If applicable, press RDY to place the printer
Appendix |