Chapter 5 Setup Menu

FCD-IPMInstallation and Operation Manual

 

 

SHDSL Parameters

SHDSL parameters of FCD-IPM can be configured via SHDSL Parameters menu.

To configure the SHDSL parameters:

1.From the SHDSL Settings menu appears (see Figure 5-33), type 1. The SHDSL Parameters menu appears (see Figure 5-34).

2.Type 1 to 6 to toggle between available values of the following parameters:

Note When selecting line mode of FCD-IPM with SHDSL interface, you must also specify appropriate E1 master timing:

STU-C mode – Internal or Sublink 1 (for FCD-IPM units with sublink)

STU-R mode – Link 1.

SHDSL Parameters (Device name - FCD-IPM)

----------------

 

1.

Line Mode

: [STU-R]

2.

Standard

: [Annex B]

3.

PSD

: [Symmetric]

4.

SNR Margin

: [0 dB]

5.

SNR Margin Threshold

: 0

6.

Loop Attn. Threshold

: 0

Press the number to edit or ESC to return to the previous screen

 

 

Figure 5-34. SHDSL Parameters Menu

 

 

Table 5-15. SHDSL Parameters

 

 

 

Parameters

Possible Values

Description

 

 

 

Line Mode

 

Operation mode of FCD-IPM with SHDSL interface:

 

STU-C

Central Office

 

STU-R

Customer Premises

 

 

 

Standard

Annex A/B

SHDSL standard compatibility (Annex A or Annex B)

 

 

 

5-30 Interface Parameters Menu

Page 120
Image 120