Chapter 5 Setup Menu FCD-IPM Installation and Operation Manual
5-30 Interface Parameters Menu
SHDSL Parameters
SHDSL parameters of FCD-IPM can be configured via SHDSL Parameters menu.
To configure the SHDSL parameters:
1. From the SHDSL Settings menu appears (see Figure 5-33), type 1.
The SHDSL Parameters menu appears (see Figure 5-34).
2. Type 1 to 6 to toggle between available values of the following parameters:
When selecting line mode of FCD-IPM with SHDSL interface, you must also specify
appropriate E1 master timing:
STU-C mode – Internal or Sublink 1 (for FCD-IPM units with sublink)
STU-R mode – Link 1.
SHDSL Parameters (Device name - FCD-IPM)
----------------
1. Line Mode : [STU-R]
2. Standard : [Annex B]
3. PSD : [Symmetric]
4. SNR Margin : [0 dB]
5. SNR Margin Threshold : 0
6. Loop Attn. Threshold : 0
Press the number to edit or ESC to return to the previous screen
Figure 5-34. SHDSL Parameters Menu
Table 5-15. SHDSL Parameters
Parameters Possible Values Description
Line Mode
STU-C
STU-R
Operation mode of FCD-IPM with SHDSL interface:
Central Office
Customer Premises
Standard Annex A/B SHDSL standard compatibility (Annex A or Annex B)
Note