Chapter 3 Operation FCD-IPM Installation and Operation Manual
3-6 Connecting to the ASCII Terminal
Figure 3-2. Connecting to Terminal Emulator
To setup the terminal:
1. Set the terminal to work at a baud rate of 9.6 kbps, No Parity, 8 Data Bits.
2. Set the hardware control to OFF.
3. Switch on FCD-IPM.
The operational screen is displayed.
To initiate the login message:
Press <Enter> several times.
Password Protection
Using a password prevents unauthorized personnel from changing configuration
parameters.
Before you can access any configuration menus you will be prompted for login.
To logon:
Enter the correct password. The factory default password is 1234.
The password can be changed or removed during configuration. For more
information, refer to Chapter 4.
1. Use of Password protection for the configuration module is recommended.
Always use the Exit option in the Main Menu once the unit has been
configured. Using the Exit option will force personnel requiring access to the
configuration module to use password.
2. Password verification is case sensitive. Once the password is set, use the same
case that you used when typing in the password.
3. To enable E1/T1 parameter configuration the supervisor password must be
used. Using the login password disables E1/T1 menu viewing.