FCD-IPMInstallation and Operation ManualChapter 5 Setup Menu

 

 

Table 5-20. E1 Link1 Parameters

 

 

 

Parameters

Possible Values

Description

 

 

 

Frame Type

G732N

2 frames per multiframe. Time slot 16 can be used for user data.

 

G732S

16 frames per multiframe. Time slot 16 is used for the Channel

 

 

Associated Signaling (CAS).

 

 

 

CRC-4

On, Off

Cyclic Redundancy Check – enables or disables calculation of

 

 

4-bits check sum in order to detect errors in frames

 

 

 

Sync

 

Defines the time required for the link to return to normal

 

 

operation after a red alarm event has terminated.

 

FAST

1 second

 

AT&T 62411

10 seconds

 

CCITT

100 msec.

 

 

 

Idle Code

00 to FF

Sets the value to be transmitted on the NC time slots

 

 

 

Rx Gain

12 dB, 30 dB

Sets the maximum receive sensitivity for the E1 interface

 

 

 

Remote Alarm

 

When configuring this parameter from the E1 Parameters menu,

Indication (for

 

select this parameter to determine whether to transmit a yellow

FCD-IPM with a

 

alarm indication on the E1 sublink when Link 1 is in yellow

Sublink)

 

alarm state.

 

 

When configuring this parameter from the Sublink E1

 

 

Parameters menu, select this parameter to determine whether to

 

 

transmit a yellow alarm indication on Link 1 when sublink E1 is

 

 

in either yellow or red alarm state.

 

 

Note: When Link 1 is in red alarm state, an “all ones” indication

 

 

is sent to all of the E1 sublinks.

Out-Of-Service

Signaling (for FCD-IPM with a

Sublink) Mark

Determines the value of the A, B signaling bits sent to Link 1 when the sublink is in the Out-Of-Service state. The C and D signaling bits are not affected.

Both A and B signaling bits are forced to '1' during out-of-service period

 

Space

Both A and B signaling bits are forced to '0' during out-of-service

 

 

period

 

Mark-space

The A and B signaling bits are forced to '1' for 2.5 seconds, then

 

 

shift to the '0' state until the out-of-service period ends

 

Space-mark

The A and B signaling bits are forced to '0' for 2.5 seconds, then

 

 

shift to the '1' state until the out-of-service period ends.

 

 

 

Sublink Status

Enable or Disable

 

(for FCD-IPM

 

 

with a Sublink)

 

 

 

 

 

Interface Parameters Menu

5-57

Page 147
Image 147
RAD Data comm Modular Access Device with Integrated Router, E1/T1 operation manual 20. E1 Link1 Parameters, Ccitt