Chapter 5 Setup MenuFCD-IPMInstallation and Operation Manual

 

Table 5-18.

T1 Parameters Link1 Parameters (Cont.)

 

 

 

Parameters

Possible Values

Description

 

 

 

Sync

 

Defines the time required for the link to return to normal

 

 

operation after a red alarm event has terminated.

 

FAST

1 second

 

AT&T 62411

10 seconds

 

 

 

Idle Code

00 to FF

Sets the value to be transmitted on the NC time slots

 

 

 

Rx Gain

30 dB, 36 dB

Sets the maximum receive sensitivity for the T1 interface

 

 

 

Remote Alarm

 

When configuring this parameter from the T1 Parameters menu,

Indication (for

 

select this parameter to determine whether to transmit a yellow

FCD-IPM with a

 

alarm indication on the T1 sublink when Link 1 is in yellow

Sublink)

 

alarm state.

 

 

When configuring this parameter from the Sublink T1

 

 

Parameters menu, select this parameter to determine whether to

 

 

transmit a yellow alarm indication on Link 1 when sublink T1 is

 

 

in either yellow or red alarm state.

 

 

Note: When Link 1 is in red alarm state, an “all ones” indication

 

 

is sent to all of the T1 sublinks.

Out-Of-Service

Signaling (for FCD-IPM with a

sublink)MARK

Determines the value of the A, B signaling bits sent to Link 1 when the sublink is in the Out-Of-Service state. The C and D signaling bits are not affected.

Both A and B signaling bits are forced to '1' during out-of-service period

 

SPACE

Both A and B signaling bits are forced to '0' during out-of-service

 

 

period

 

MARK-SPACE

The A and B signaling bits are forced to '1' for 2.5 seconds, then

 

 

shift to the '0' state until the out-of-service period ends

 

SPACE-MARK

The A and B signaling bits are forced to '0' for 2.5 seconds, then

 

 

shift to the '1' state until the out-of-service period ends.

 

 

 

Sublink Status

Enable or Disable

 

(for FCD-IPM

 

 

with a sublink)

 

 

 

 

 

Additional Cards Parameters

Select this option to allow you to select the card for which parameters are to be displayed. A toggle option appears on the bottom of the screen. Use the Space bar to toggle between the card types. Press Enter to access the parameters screen.

5-42 Interface Parameters Menu

Page 132
Image 132
RAD Data comm E1/T1 operation manual T1 Parameters Link1 Parameters, Additional Cards Parameters