Chapter 5 Setup Menu

FCD-IPMInstallation and Operation Manual

 

 

Main Link Local Analog Loopback – In this mode the data transmitted from FCD-IPM to the T1 line is sent back to the receive path instead of the received data from the T1 line. The loopback is shown in Figure 5-48.

FCD-IPM

Link1 T1 Interface

T1

Service

Loopback

Figure 5-48. Local Analog Loopback

Sublink Local Analog Loopback (for FCD-IPM with a sublink) – In this mode the data transmitted from FCD-IPM to the sub T1 line is sent back to the receive path instead of the received data from the sub T1 line. The loopback is shown in Figure 5-49.

FCD-IPM (T1 with Sub Link)

Router/Bridge

Link1

 

T1

 

Service

 

Sub Link T1

 

Interface

 

T1 Service

 

or PABX

Loopback

Figure 5-49. Local Analog Loopback for T1 and Sub T1 Links

Voice Diagnostic Tools

There are three voice diagnostic tools that are available for FCD-IPM. They can be set independently for each voice port:

Tone injection to the voice port – a 1 kHz signal is injected into the receive voice port path, replacing any receive signal from T1

Tone injection to the T1 – a 1 kHz signal is injected into the receive voice port path, replacing any receive signal from T1, and injected into the T1 transmit path, replacing any transmit signal to T1

Remote port loopback – the voice port signal which is received from T1 is transmitted back to T1.

5-40 Interface Parameters Menu

Page 130
Image 130
RAD Data comm E1/T1, Modular Access Device with Integrated Router Local Analog Loopback for T1 and Sub T1 Links