FCD-IPMInstallation and Operation Manual

Chapter 5 Setup Menu

 

 

When CRC-4 is enabled, diagnostics are available for the last 24 hours collected in 15-minute intervals (similar to the AT&T PUB 54016).

T1 Setup Menu

T1 SETUP: LINK 1 (Device name - FCD-IPM)

----------------

1.Clock master : [Link 1]

2.Multiplier : [64 kbps]

3.Time slots mapping

4.General Diagnostics

5.T1 parameters

6.Additional Cards parameters

7.Alarms filter

8.Advanced Setup

ESC - Return to previous menu

 

 

Figure 5-41. T1 Setup Menu

 

 

Table 5-17. T1 Setup Parameters

 

 

 

Parameters

Possible Values

Description

 

 

 

Clock Master

 

Selects the source clock that synchronizes the whole T1

 

Internal

network

 

 

 

 

FCD-IPM generates the system source clock from an internal

 

Link 1

clock oscillator.

 

 

 

 

FCD-IPM recovers the clock from the data received from the

 

 

T1 link1

 

I/O1 SUB T1

For FCD-IPM with a sublink:

 

 

 

I/O2 SUB T1

 

 

FIX SUB T1

FCD-IPM recovers the clock from the data received from one

 

of the T1 sublinks

 

 

 

 

 

Multiplier

56 kbps, 64 kbps

Sets the data rate of each DATA time slot.

 

 

 

Interface Parameters Menu

5-35

Page 125
Image 125
RAD Data comm Modular Access Device with Integrated Router, E1/T1 T1 Setup Menu, 17. T1 Setup Parameters, O1 SUB T1