Chapter 5 Setup MenuFCD-IPMInstallation and Operation Manual

 

Table 5-24. Frame Relay Link Parameters

 

 

Parameters

Description

 

 

Self Learn

Specifies whether FCD-IPM will self learn the maintenance protocol on the

DLCI/Maintenance

Frame Relay link and the existing DLCIs with their status (UP or DOWN).

 

When this parameter is disabled (OFF), you need to configure the

 

maintenance protocol and the DLCIs manually.

 

 

CLLM Status

Specifies whether CLLM frames, used for congestion indication, will be

 

supported (ON) or not (OFF).

Maintenance Protocol

Specifies the maintenance protocol of the Frame Relay link: T1.617/ANNEX

 

D, Q.933/ANNEX A, LMI or None. This parameter can only be configured if

 

Self learn DLCI /Maintenance parameter is disabled (OFF).

 

 

Polling Interval

Specifies the number of seconds between transmission of two successive status

 

enquiry frames.

 

 

Full Enquiry Interval

Specifies the number of polling intervals after which a full status request frame

 

is transmitted.

 

 

Error Threshold

Specifies the number of unacknowledged monitored events (status enquiry

 

frames and full status enquiry frames) that can occur in a sliding monitored

 

events window before the link is declared DOWN.

 

 

Monitored Events

Specifies the number of monitored events (status enquiry frames and full status

 

enquiry frames) in a sliding monitored events window.

 

 

5-70 Interface Parameters Menu

Page 160
Image 160
RAD Data comm E1/T1 operation manual Frame Relay Link Parameters, Enquiry frames in a sliding monitored events window