Chapter 4 ConfigurationFCD-IPMInstallation and Operation Manual

Table 4-8. SHDSL Status Screen Parameters

Parameters

Possible Values

Description

 

 

 

 

 

Op. State

 

Operational status of the SHDSL link

 

 

Idle

Link is down

 

 

Handshake, Training,

FCD-IPM is establishing communication link with remote

 

 

Framer Sync

device

 

 

Data

Data is being transferred over the SHDSL link

 

 

 

 

 

Bitrate

 

Actual line rate after the handshake process is completed

 

 

 

 

 

Loop Attenuation

 

Difference (in dB) between the power transmitted from FCD-

 

 

 

IPM and the power received by the unit operating at the other

 

 

 

side of the application

 

 

 

 

 

Transmit Power

 

Level of power (in dB) which is transmitted on the SHDSL line

 

 

 

 

 

SNR

 

Signal-to-noise ratio, difference (in dB) between signal and

 

 

 

background noise

 

 

 

 

 

SHDSL DSP Version,

 

SHDSL DSP and driver revisions

SHDSL Driver

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

Loop Attenuation, Transmit Power and SNR are displayed only when OP. State is in

 

Data mode.

 

 

 

 

 

 

 

 

 

 

 

 

SHDSL STATUS

( Device name - FCD-IPM )

 

 

Op. State

 

: Data

 

 

 

Framer Status

: Sync

 

 

 

Bitrate

 

:

1032

 

 

 

Loop Attenuation

:

5

 

 

 

Transmit Power

:

7.5

 

 

 

SNR

 

:

14

 

 

 

SHDSL DSP Version

:

1

 

 

 

SHDSL Driver Version:

R1.7.1

 

 

 

--------

CRC

ES

SES

LOSW

LOSWS

UAS

----

---- ----

----

-----

----

15 Min :

3

1

0

0

0

0

24 hours :

0

0

0

0

0

0

ESC - previous menu

M - More

R - Refresh

C - Clear statistics

 

 

 

 

 

 

 

Figure 4-40. SHDSL Status