Chapter 5 Setup Menu FCD-IPM Installation and Operation Manual
5-92 WAN Economy Menu
Table 5-32. Connection On Demand Parameters (Cont.)
Parameters Possible Values Description
Minimum Time
Between 2
Connections
Determines how much time there must be between a line being
terminated and then reactivated. This option is only used when
upon power up is chosen in start connection. All other options are
determined by the frame traffic
Minimum Time
Between 2
Disconnections
Determines the minimum time between two disconnections. Using
this option allows you to determine a minimum time-up. This
option overrides other terminate connection options
Connect Manually Activates a line immediately. This option overrides any other
connection option, including minimum time between 2 connections
Disconnect Manually Terminates a line immediately. This option overrides any other
terminate option, including minimum time between 2
disconnections
The following examples demonstrate how COD can be used.
Example 1:
A company needs their FCD-IPM to be connected to the Internet 24 hours a day.
Therefore the following must be defined:
Start connection is upon power up
Terminate Connection is never (see Figure 5-92).
ISDN
INTERNET
The connection is
permanent
Connection is never
terminated
FCD-IPM
Figure 5-92. Permanent Connection