FCD-IPMInstallation and Operation Manual

Chapter 3 Operation

 

 

Fault Indications

If a fault occurs, the following alarm indicators light up, and data transfer may be interrupted:

LAN ERR indicator lights when LAN interface indicates an error

LINK ERR indicator lights when LINK interface indicates an error

RED ALARM indicator lights when T1 interface detects red alarm

YELLOW ALARM indicator lights when T1 interface detects yellow alarm

LOC SYNC LOSS indicator lights when the E1 interface detects local sync loss

REM SYNC LOSS indicator lights when the E1 interface detects remote sync loss.

To obtain additional information, observe the state of the other indicators and then refer to Chapter 6 for troubleshooting information:

Turning Off

Set the FCD-IPM power switch, on the rear panel of the unit, to OFF.

3.4 Connecting to the ASCII Terminal

FCD-IPM features a setup program that is invoked and run from an ASCII terminal or a PC emulator. The terminal/terminal emulator is connected to the RJ-45 CONTROL port on the FCD-IPM front panel (see Figure 3-2).

Connecting the Terminal Emulator

To connect the terminal emulator:

1.Attach the cable to the RS-232 port on the PC.

2.Attach the other end of the cable to the CONTROL port on the FCD-IPM front panel.

Connecting to the ASCII Terminal