FCD-IPMInstallation and Operation Manual

Chapter 5 Setup Menu

 

 

Signaling Feedback

This parameter is set to:

Enabled

feedback of the on/off hook signaling that was received from T1 is

 

transmitted back to T1

Disabled

feedback of the on/off hook signaling that was received from T1 is not

 

transmitted back to T1.

Out of Service Method

This parameter specifies the on/off hook signaling in FXO when an Out of Service condition is indicated in the T1 link. The values are:

Forced Idle signaling is held on hook for the duration of the Out of Service condition Forced Busy signaling is held off hook for the duration of the Out of Service condition.

E & M Voice Interface

VOICE PARAMETERS: (Device name - FCD-IPM I/O1 Voice)

-----------------

1.TX/RX gains

2.

Interface type

: [4W]

3.

E&M type

: [A bit]

4.

Coding law

: [LAW]

5.E signal from the T1 on: [A bit]

6.M signal to the T1 on : [A bit]

7.Default ABCD to the T1 : [0000]

8.Out of Service method : [Forced Idle]

ESC - Return to previous menu

Choose one of the above:

Figure 5-53. E & M Voice Interface

RX/TX Gains

Select this parameter to specify the nominal input level of the receive and transmit paths for each voice port. The input level range is –10 to +5 dBm.

Interface Type

This parameter specifies the interface type:

2W

two-wire interface

4W

four-wire interface.

Interface Parameters Menu

5-47

Page 137
Image 137
RAD Data comm Modular Access Device with Integrated Router, E1/T1 operation manual This parameter is set to, Voice Interface