Chapter 4 Configuration FCD-IPM Installation and Operation Manual
4-38 View Menu
To refresh or clear statistics:
From the SHDSL Status screen, type R to refresh the display or type C to clear
the SHDSL statistics.
E1/T1 Diagnostics
Select this option to display error information for the E1/T1 link. This information
enables you to evaluate the line quality. The errors are accumulated in 15-minute
intervals. FCD-IPM keeps up to 96 intervals (for 24 hours).
In addition, there is a rolling 24 hour total of each error parameter. The rolling
total is displayed for the interval parameter called TOTAL. The interval parameter
called CURRENT is the open interval, which did not yet reach 15 minutes. The
errors counted in the CURRENT interval are not included in the TOTAL interval.
The amount of time that has elapsed is displayed on the right of the CURRENT
parameter line. T1 diagnostics are available only when frame mode is ESF. E1
diagnostics are available only when CRC-4 is enabled.
T1 DIAGNOSTICS - LINK 1 (Device name - FCD-IPM)
-----------------------
INTERVAL ES UAS SES BES LOFC CSS DM
-------- ----- ----- ----- ----- ----- ----- -----
CURRENT 1 163 173 1 1 0 02.53 min
ESC - previous menu | R - Refresh | C - Clear diagnostics
Figure 4-42. T1 Diagnostics
E1 DIAGNOSTICS - LINK 1 (Device name - FCD-IPM)
--------------
INTERVAL ES UAS SES BES LOFC CSS DM
CURRENT 0 0 0 0 0 0 06.15 min
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 1 0 0 1 0 0
Total 1 0 0 1 0 0 0
ESC – previous menu | R – Refresh | C – Clear diagnostics
Figure 4-43. E1 Diagnostics