Chapter 5: Installation |
If a longer power cable run is required, use the supplied power cable to connect to the unit, then use a suitable connector block to connect the free end to the extension cable. The supplied power cable has a
Longer power cable runs may require larger wire gauges to minimize any voltage drop in the cable. In order to determine the correct supply cable size if the power cable must be extended, estimate the length of cable between the vessel’s main power source and the connector block, then select the wire size determined by the distance as indicated in Table
Table 5-1: Maximum Power Cable Extension Lengths
Power Cable Core mm2: | 1.5 | 2.0 | 2.5 | 4.0 | 6.0 | 10.0 |
Equivalent AWG: | 16 | 15 | 14 | 12 | 10 | 8 |
|
|
|
|
|
|
|
Maximum Extension (feet): | 36 | 49 | 65 | 98 | 147 | 230 |
|
|
|
|
|
|
|
Maximum Extension (meters): | 11.0 | 15.0 | 20.0 | 30.0 | 45.0 | 70.0 |
|
|
|
|
|
|
|
The DC power and NMEA inputs/outputs should be connected to the POWER/NMEA connector at the rear of the Plotter. The connector pin functions are detailed in Table
Table 5-2: Power/NMEA Connections
Function | Color |
|
|
Battery negative | Black |
|
|
Battery positive | Red |
|
|
NMEA data input (+ve) | White |
|
|
NMEA input | Green |
|
|
Not connected | Gray |
|
|
NMEA data out | Yellow |
|
|
NMEA Data output common | Brown |
|
|
Not connected | Screen |
|
|