Raymarine 300 manual 2 Power/NMEA Connections, Function, Color

Models: 300

1 136
Download 136 pages 59.73 Kb
Page 107
Image 107
Table 5-2:Power/NMEA Connections

Chapter 5: Installation

5-13

If a longer power cable run is required, use the supplied power cable to connect to the unit, then use a suitable connector block to connect the free end to the extension cable. The supplied power cable has a cross-section of 2.0mm2 (15 AWG).

Longer power cable runs may require larger wire gauges to minimize any voltage drop in the cable. In order to determine the correct supply cable size if the power cable must be extended, estimate the length of cable between the vessel’s main power source and the connector block, then select the wire size determined by the distance as indicated in Table 5-1.

Table 5-1: Maximum Power Cable Extension Lengths

Power Cable Core mm2:

1.5

2.0

2.5

4.0

6.0

10.0

Equivalent AWG:

16

15

14

12

10

8

 

 

 

 

 

 

 

Maximum Extension (feet):

36

49

65

98

147

230

 

 

 

 

 

 

 

Maximum Extension (meters):

11.0

15.0

20.0

30.0

45.0

70.0

 

 

 

 

 

 

 

The DC power and NMEA inputs/outputs should be connected to the POWER/NMEA connector at the rear of the Plotter. The connector pin functions are detailed in Table 5-2.

Table 5-2:Power/NMEA Connections

Function

Color

 

 

Battery negative

Black

 

 

Battery positive

Red

 

 

NMEA data input (+ve)

White

 

 

NMEA input (-ve) -common

Green

 

 

Not connected

Gray

 

 

NMEA data out

Yellow

 

 

NMEA Data output common

Brown

 

 

Not connected

Screen

 

 