BUILT-IN HARD DISK
Hard disk
Recording areas
The recording areas on the hard disk (normal recording area: 80%,
alarm recording area: 19%, archive area: 1%) are established automatically when the power for the digital video recorder is turned on. Images are recorded in the normal recording area when the REC/STOP button is pressed, and they are recorded in the alarm recording area when an alarm occurs. This is called the default condition, and the following detailed settings can be confirmed in the sections on “RECORDING IMAGES IN THE NORMAL RECORDING AREA” and “RECORDING IMAGES IN THE ALARM RECORDING AREA” which are explained later. Furthermore, settings such as the recording areas and picture quality can be changed using the menu screens.
C Archive area 1%
BAlarm recording area
A Normal recording area
•When the REC/STOP button is pressed while monitoring is in progress, images are recorded in the normal recording area.
•When start and end times are entered for each day of the week and are then enabled, timer recording is automatically carried out in the normal recording area between the times that have been set.
B Alarm recording area
ALARM REC MODE SET menu settings are required.
•Alarm recording is enabled when ALARM RECORDING is set. When a suspicious person is detected by the switch or motion sensor that is connected to the alarm input terminal, an alarm is recorded in the alarm recording area.
•
19%
80%
A Normal recording area
Hard disk recording areas
C Archive area
This is the area for copying important images from the normal recording area and the alarm recording area. The size of the archive area can be set to a maximum of 10 GB (12.5% of total capacity when using an
Menu screen (initial setting)
This can be displayed by pressing the MENU button.
| <RECORDING AREA SET> |
|
|
|
|
|
|
| |
TOTAL CAPACITY | : | 80GB |
|
|
|
|
| ||
NORMAL RECORDING AREA | : | 80 | % |
|
| A |
| A | |
AREA | FULL RESET |
|
|
|
|
|
|
| |
ALARM RECORDING AREA | : | 19 | % |
|
| B |
| B | |
|
|
| |||||||
AREA | FULL RESET |
|
|
|
|
|
|
| |
ARCHIVE | AREA | : | 1 | % |
|
| C |
|
|
|
|
|
| ||||||
AREA | FULL RESET |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
CAUTION : WHEN THE AREA SETTING IS CHANGED.
THE WHOLE AREA WILL BE INITIALIZED !
1Picture quality: ENHANCED
Picture quality can be selected from five options.
The recording speed changes in accordance with the picture quality selected.
2Recording method: Can be set to FRAME or FIELD.
The recording speed changes in accordance with the method selected.
3Audio recording: Can be set to ON or OFF.
4Recording speed: Shows the recording interval and the recording time.
Refer to the recording speed table for further details.
5Alarm recording setting: Can be set to ON or OFF.
When alarm recordings are to be made, select a setting such as MODE1 for the OFF setting. The recording speed and alarm duration will be displayed
ASetting screen for normal recording area picture quality, recording speed, etc.
<NORMAL REC MODE | SET> |
|
| 1 | |
PICTURE QUALITY |
| : ENHANCED |
|
| |
|
|
| |||
FRAME/FIELD RECORDING : FIELD |
| 2 | |||
| |||||
AUDIO RECORDING |
| : OFF |
| 3 | |
|
| ||||
REC CYCLE : | 0.10SEC | ( 54H) |
| 4 | |
|
BSetting screen for alarm recording area picture quality, recording speed, etc.
|
|
|
|
|
| <ALARM REC |
| MODE SET> |
|
|
|
|
|
|
|
| 1 | ||||||||||||
PICTURE QUALITY | : |
|
| ENHANCED |
|
|
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||||||||
FRAME/FIELD RECORDING | : |
|
| FIELD |
|
|
|
|
| 2 |
| ||||||||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||||||||
AUDIO | RECORDING | : |
|
| OFF |
|
|
|
|
| 3 | ||||||||||||||||||
|
|
|
|
|
|
| |||||||||||||||||||||||
ALARM | RECORDING | : |
|
| OFF |
|
|
|
|
| 5 |
| |||||||||||||||||
|
|
|
|
|
|
|
| ||||||||||||||||||||||
| REC | CYCLE : 0.10SEC. |
|
|
| DURATION: | 1SEC |
| 4 | ||||||||||||||||||||
|
|
|
|
| |||||||||||||||||||||||||
: |
| ¤¤¤ |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
| REC | CYCLE : ¤¤¤ SEC. |
| DURATION: | ¤¤¤ |
|
|
|
|
|
|
|
|
| |||||||||||||||
=> | (46400 ALARMS CAN BE RECORDED) |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
ALARM | TRIGGER | : |
|
| ALARM |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
| MOTION SENSOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 | English |