ALARM REC MODE SET SETTING
1 Use the jog dial to move the cursor to the MOTION SENSOR setting, and then turn the shuttle dial clockwise.
The motion sensor screen appears on the normal screen.
: | ON |
|
|
| |||||||
| REC CYCLE : A0.13SEC. DURATION: 5SEC |
| |||||||||
| => (01677 ALARMS CAN BE RECORDED) |
|
| ||||||||
ALARM TRIGGER |
|
|
| : | ALARM |
|
|
| |||
| MOTION SENSOR |
|
|
|
|
|
|
| |||
- | - | - | - | - |
| - | - | - | - | - | |
| |||||||||||
| |||||||||||
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
- | - | - | - | - |
| - | - | - | - | - | |
|
| LEVEL : OFF |
|
| EXIT |
|
|
|
2 Turn the jog dial to set the sensor position, and then turn the shuttle dial clockwise.
Since the sensor goes from OFF
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
|
| LEVEL : OFF |
| EXIT |
|
|
|
3 Use the jog dial to move the cursor to “ LEVEL: OFF” , turn the shuttle dial clockwise, and then use the jog dial to set the sensitivity (example: “ 6” ).
Display examples: Sensitivity settings
•OFF: Sensor does not operate
•1 to 10: Sensor operates (the lower the value, the greater the sensitivity)
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
|
| LEVEL : 6 |
|
| EXIT |
|
|
|
Note: You can check the sensitivity in the setting screen. When an alarm is detected, the buzzer (a beeping noise) sounds. If the sensitivity is too strong, an alarm can be triggered by variations in light. Make the setting that is appropriate for the area being monitored.
4 Turn the shuttle dial clockwise twice.
This completes the motion sensor settings, and the display is returned to the ALARM REC MODE SET screen.
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | ú | ú | ú | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - |
|
| LEVEL : 6 |
|
| EXIT |
|
|
|
5 Press the EXIT/OSD button.
The display returns to the normal screen.
EXIT/OSD
Note: Change the ALARM setting for the ALARM set item in the BUZZER SET menu in MAIN MENU 2 to “ON”.
58 | English |