
RECORDING IMAGES IN THE ALARM RECORDING AREA
Alarm recording
Alarm images are recorded
1
MENU
2
ALARM
1Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and set the date and time. After the setting has been made, press the EXIT/OSD button, the date and time appear in the operating display. (See page 42.)
2Set alarm recording.
•Press the MENU button to display the ALARM REC MODE SET menu from the MAIN MENU screen. Then change the ALARM RECORDING setting to the desired alarm recording setting (MODE1, 2, 3 or 4) and change the ALARM TRIGGER setting. (See page 54 ~ 56.)
•Press the MENU button, to display the BUZZER SET menu from the MAIN MENU 2 screen, and change the ALARM setting to “ON”. (See page 62.)
•Press the EXIT/OSD button to return to the normal screen.
Suspicious person detection
When an alarm occurs, “ALARM” appears in the operating display, the ALARM indicator flashes and alarm recording (a symbol) starts. Alarm images are recorded in the alarm recording area. Furthermore, the number of alarms in the operating display is increased by one each time an alarm occurs.
<MAIN MENU 1>
| 1.LANGUAGE/CLOCK SET |
|
|
| ||||
| 2.VIDEO INPUT SET |
|
|
|
| |||
| 3.RECORDING AREA SET |
|
|
| ||||
| 4.RECORDING CONDITIONS SET |
| ||||||
|
| <LANGUAGE/LANGUE/IDIOMA> | ||||||
|
| ENGLISH |
|
|
|
|
| |
|
| <CLOCK SET> |
|
|
|
| ||
|
| 00:00:00 |
|
| ||||
|
| <ALARM REC | MODE SET> | |||||
PICTURE QUALITY | : | ENHANCED | ||||||
FRAME/FIELD RECORDING | : | FIELD |
|
|
|
| ||
AUDIO RECORDING | : | OFF |
|
|
|
| ||
ALARM RECORDING | : | MODE1 |
|
|
|
| ||
REC CYCLE : 0.10SEC. |
| DURATION: 1SEC | ||||||
: | ¤¤¤ |
|
|
|
|
REC CYCLE | : ¤¤¤ | SEC. | DURATION: ¤¤¤ |
=> (46400 | ALARMS | CAN BE RECORDED) | |
ALARM TRIGGER | : | ALARM | |
MOTION SENSOR |
|
18:10:25
10SEC
Note: Normal recording and timer recording stop when an alarm occurs during normal recording or timer recording.
Ending alarm recording
3 | Recording ends after the end of the alarm duration period (default setting: 1 sec). |
| |
| The “a” and ALARM displays stop flashing and recording stops. |
| Note: When the remaining area in the alarm recording area reaches 1%, the |
| ALARM FULL indicator on the front panel flashes. If recording is continued |
| under these conditions, the recording area is filled and the recording |
| stops. In the RECORDING AREA SET settings, carry out the AREA FULL |
| RESET operation for the alarm recording area. |
| Overwriting will be canceled and recording will be possible from the |
| beginning again. (See page 48.) |
The number of alarms is counted.
POWER | FULL | ALARM FULL | LOC |
English | 17 |