INTERFACE SPECIFICATIONS

RS-232C

9-pin connector specifications

1

2

3

4

5

Pin No.

Signal

Operation

Signal direction

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

RXD

Receive data

Computer Digital video recorder

 

 

 

 

 

 

 

 

 

 

3

TXD

Transmit data

Digital video recorder Computer

6

 

7

8

9

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

GND

Ground

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

7

RTS

Request to send

Digital video recorder Computer

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

 

 

Communication protocol

Communication is carried out in units of 1 byte. After the computer transmits one byte of data, it waits for a response from the digital video recorder, and then transmits the next byte of data.

To start sending commands, an ON (F6) command is sent. The digital video recorder will continue to receive commands until an OFF (F7) command is sent to stop. The digital video recorder sends an ACK (OA) each time it receives a command.

See Table 4 - Command Table on page 75.

RS-485

Data format

Mode

Asynchronous

Character length

8 bits

Data transmit speed

2400, 4800, 9600, 19200 bps

Parity

None

Stop bit

1

 

 

Communication protocol

A proprietary Sanyo protocol (SSP: Security Serial Protocol) is used. It is recommended that a special controller be used. Contact the place of purchase for further details on obtaining a special controller.

English

73

Page 74
Image 74
Sanyo Digital Video Recorder, DSR-3000 Interface Specifications, RS-232C, RS-485, Pin connector specifications