TIMER

Timer recording starts when the timer setting time is reached.

a” appears in the operating display and the images being monitored are recorded in the normal recording area. Recording onto the hard disk proceeds automatically (default setting) according to the following settings. The settings can be changed between long-period recording and high-quality recording in five steps. (See page 49.)

Hard disk recording areas: Normal recording area: 80% Alarm recording area: 19% Archive area: 1%

Picture quality: EN (Enhanced)

Recording method: Field

Recording speed: 0.10 seconds (54H)

Note: Playback is possible during recording. When the PLAY/STOP button is pressed during recording, c appears in the operating display and images are played back from the point where recording began. (See page 20.)

Timer recording stops when the set end time is reached.

The TIMER indicator swithes off and the recording symbol (a) disappears from the operating display and recording stops.

Note:

Press the TIMER button to stop timer recording. Timer recording then stops.

When the remaining area in the normal recording area drops below the set amount, the FULL indicator on the front panel flashes. If recording continues under these conditions, the recording area becomes full and recording stops. In the RECORDING AREA SET settings, carry out the AREA FULL RESET operation for the normal recording area.

Recording will then be possible from the beginning again. (See page 48.)