KEY OPERATOR PROGRAMS

Initial Status Setting

The copier will assume the initial settings when it is turned on, when the CLEAR ALL ( CA ) key is pressed, or when the auto clear interval has elapsed after a copy run. Use this program to establish the initial settings.

When the “INITIAL STATUS SETTING.” key is pressed, the following display will appear.

KEY OPERATOR PROGRAMS

 

INITIAL STATUS SETTING.

OK

SET THE INITIAL STATUS.

 

ESTABLISH NEW INITIAL

 

SETTINGS.

 

1/4

1/4

RETURN TO THE FACTORY DEFAULT

SETTINGS.

To establish new initial settings

1.Press the “ESTABLISH NEW INITIAL SETTINGS.” key.

2.Select all initial settings on the operation panel.

The following functions cannot be set:

Number of copies, XY zoom, automatic copy ratio selection, interrupt, special functions, information, stapling position (for an optional finisher (AR-FN3)) and LCD contrast.

3.Press the “OK” key.

To return to the factory default settings

Press the “RETURN TO THE FACTORY DEFAULT SETTINGS.” key.

Stream Feeding Mode

This program is used to enable the stream feeding mode of the document feeder. When the stream feeding mode is enabled, additional originals which are set in the document feeder tray within 5 seconds after the previous original was fed will be fed and copied automatically.

To enable the stream feeding mode, press the check box of “STREAM FEEDING MODE.” to display a check mark in the check box.

To disable this mode, press the check box of this program again to clear the check mark in the check box.

The stream feeding mode will only function when the group mode has been selected.

KEY OPERATOR’S GUIDE8

Key operator programs CHAPTER

8-19

Page 159
Image 159
Sharp AR-507 Initial Status Setting, To establish new initial settings, To return to the factory default settings