From the previous page

V5 Set whether the station number information should be output or not

·Set whether the station number information should be output or not on the parameter address 007763(8).

Whether the station 007763(8) number information

should be output or not

00(H): Do not output

01(H): Output

The station number information is output on the next byte of the flag area (24 bytes.)

V5 Set top address of flag area

File address: OCT (octal), word

File number/flag: HEX (hexadecimal), byte

·Set the top address of the flag area (24 bytes) in order to monitor the communication condition and PC operation condition on the parameter address 007764 to 007767(8).

·Flag area uses 24 bytes regardless number of connecting stations.

 

 

 

Contents

Initial value

 

 

 

 

007764(8)

 

 

 

Lower

E0(H)

 

 

 

Byte address

 

 

 

 

 

 

01E0(H)000740(8)0740

007765(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Upper

01(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007766(8)

 

 

 

 

 

 

File number

00(H)

 

 

 

File number 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007767(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

 

 

 

 

 

80(H)

 

 

 

Output flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks

 

 

 

 

 

Output flag : ON

 

 

 

 

 

 

 

 

 

Do not output flag : OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

· The PC's input/output relays, auxiliary relays, registers etc. are all allocated individual byte

9addresses for each item. However, the JW-20CM can assign these addresses with file addressees allocated throughout the memory.

File address

 

 

Byte address

 

 

 

File address

 

Byte address

 

 

 

 

0000

 

 

 

 

004000

 

09000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I/O relay

 

 

 

 

 

 

 

Register

 

 

PCs

 

 

 

 

00377

 

 

 

 

 

 

 

 

000377

 

 

 

 

 

 

004777

 

09777

 

model

 

000400

Auxiliary relay

 

00400

 

 

 

 

 

 

 

 

 

 

 

 

005000

 

19000

 

 

 

 

 

 

 

 

 

 

 

 

000677

 

 

00677

 

PCs

PCs

 

Register

 

 

ZW

PCs

000700

Latch relay

 

00700

 

005777

 

19777

 

000777

 

00777

 

model

model

 

 

 

 

model

 

 

 

 

 

 

006000

 

29000

 

 

 

 

001000

 

 

01000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General purpose relay

 

 

 

ZW

JW

 

 

 

 

 

 

JW

001577

 

 

01577

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001600

TMR/CNT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001777

time limited contact

 

b0000

 

 

 

 

 

 

 

 

 

 

 

002000

TMR/CNT/MD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current value

 

 

 

 

 

 

015777

 

99777

 

 

 

 

003777

 

 

b17777

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

· The usable file numbers will vary with the memory module that is installed on the PC.

Name of memory module

Usable file numbers

If file number is 1, file

ZW-1MA, JW-1MAH

0 or 1

address shall be within

 

 

000000 to 037777(8).

ZW-2MA, JW-2MAH

0 or 1

(See page 13·20 and 21

 

 

ZW-3MA, JW-3MAH

0, 1, 2

for other cases.)

 

 

ZW-4MA, JW-4MAH

0, 1, 2, 3, 4, 5, 6, 7

 

 

 

 

To the next page