(3/3)

 

 

 

 

 

 

 

Address(8)

Set contents

Setting method (value, example)

JW-I/O

ZW-I/O

 

 

 

Upper 4 bits: rack

 

 

 

 

 

 

000100

Max. rack, slot number

number

 

D7 6 5 4 3 2 1 0

 

 

 

 

 

 

 

 

Lower 4 bits: rack

 

 

 

 

 

 

 

Slot: 1 Slot: 0

 

 

 

 

 

 

number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Both the number of dummy IO points,

 

 

 

 

 

60(H)

and the type of I/O modules can be

 

 

 

 

 

 

set arbitrarily.

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the number of dummy I/O points

 

 

 

 

 

64(H)

arbitrarily, and set the type of I/O

 

000100

Normal I/O table registration

 

modules autumatically.

 

 

 

 

 

 

 

 

Set the number of dummy I/O points

 

 

 

 

 

65(H)

arbitrarily, and set the type of I/O

 

 

 

 

 

 

modules automatically.

 

 

 

 

 

 

 

 

 

 

 

 

00(H)

This normally ends the setting

 

 

 

 

 

procedure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001002

Auto I/O table registaration when

00(H)

Auto registration

 

 

 

power lights ON

 

 

 

 

 

 

 

03(H)

Prohibit auto registration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

001004

Remote I/O top address

(Octal, word)

When 0200, set to 000200(8) by file

 

 

 

001005

address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

003750

Check No. of I/O bytes

00(H)

No check

 

 

 

 

 

 

 

 

 

 

45(H)

Check

 

 

 

 

 

 

 

 

 

 

 

 

 

003752

No. of I/O bytes (0 to 128 bytes)

 

 

 

 

 

 

 

• When 003750 is set to "00(H):

 

 

 

 

 

 

 

 

(Decimal, word)

When 100 bytes, set to 00100(D)

 

 

 

003753

Do not check," these addresses

 

 

 

 

 

 

 

 

 

 

do not have to be set.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop operation of the remote I/O

00(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop operation of the remote I/O

01(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Writing to EEPROM or operation

80(H)

 

 

 

 

 

 

003777

of the module/stop operation

 

————

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Writing to EEPROM or operation

81(H)

 

 

 

 

 

 

 

of the module/stop operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialize parameter setting value

08(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Set page 8·19 for initial values of the addresses above.

13