(3) Error code

When an error occurs in the JW-20CM, it stores the occurred error’s code to system memory #170 of each station’s PC.

 

 

Error

Cause

Error code stored to system memory

 

Measure

 

 

code

 

 

 

 

 

 

 

 

 

(HEX)

 

#160

 

#170

 

 

 

 

 

01

ROM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

RAM error, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the JW-20CM

 

 

03

2 port RAM error against PC, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04

2 port RAM error against

 

53(H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

communication CPU, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check the communication

 

 

11

ROM error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

12

RAM error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check for doubled allocation

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Communication LSI error, communication CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of slave station number

 

 

1F

No response

 

 

 

 

1F (H)

 

• Replace the JW-20CM

 

 

 

 

 

 

 

 

 

20

More than one token detected

 

 

 

 

20 (H)

Check the parameter setting

 

 

 

 

 

 

 

 

21

Doubled address detected

 

 

 

 

21 (H)

and switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Fault of sending section

 

 

 

 

22 (H)

Replace the JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Token does not return within the rated interval

 

 

 

 

23 (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the communication cable

 

 

2A

Overflow of receiving buffer.

 

 

 

 

2A (H)

 

 

Occurs when the upper CPU processing is delayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2B

Flame length error

 

 

 

 

2B (H)

Check the communication cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the JW-20CM

 

 

2C

Media error

 

 

 

 

2C (H)

 

 

 

 

 

 

 

 

30

EEPROM error

 

 

 

 

30 (H)

Replace the JW-20CM

8

 

 

 

 

 

 

BE

BCC error

 

 

 

 

BE (H)

Check the switch setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BF

Parameter setting error

 

 

 

 

BF (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

Communication error

 

 

 

 

C1 (H)

Check the communication

 

 

to

• After converting into octal, the lower two digits

 

 

 

 

to

 

 

 

 

 

 

 

 

 

 

FF

represent the slave station number of the current

 

 

 

 

FF (H)

cable and slave module

 

 

error. (Ex. C1(H) = 301(8)= slave station 01)

 

 

 

 

 

 

In some cases, error code 23(H) or 2A(H) is stored when inputting power. This is not an error.

8·52