(Error code)

 

 

 

 

 

 

 

● : ON, ○ : OFF

 

 

 

 

 

 

LED name

 

 

Error

Cause

Measure

80 40 20 10

8

4

2

1

code

(HEX)

 

 

 

 

 

 

 

 

 

 

○ ○ ○ ○ ○ ○ ● 01(H) ROM error, upper CPU

○ ○ ○ ○ ○ ● ○ 02(H) RAM error, upper CPU

 

 

○ ○ ○ ○ ○ ○ ● ● 03(H)

2 port RAM error against PC, upper CPU

Replace the JW-20CM

 

 

○ ○ ○ ○ ○ ● ○ ○ 04(H)

2 port RAM error against communication CPU, upper CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ○ ● ○ ○ ○ ● 11(H)

ROM error, communication CPU

 

 

 

 

 

• Check the communica-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ○ ● ○ ○ ● ○ 12(H)

RAM error, communication CPU

 

 

 

tion cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check for doubled allocation

 

 

○ ○ ○ ● ● ○ ○ ○ 18(H)

Communication LSI error, communication CPU

 

 

 

of slave station number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ○ ● ● ● ● ● 1F(H)

No response, communication CPU

 

 

 

• Replace the JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ● ○ ○ ○ ○ ○ 20(H)

More than one token detected

Check the parameter

 

 

○ ○ ● ○ ○ ○ ○ ● 21(H)

Doubled address detected

setting, switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ● ○ ○ ○ ● ○ 22(H)

Fault of sending section

Replace the JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ● ○ ○ ○ ● ● 23(H)

Token does not return within the rated interval

Check the communication cable

 

 

○ ○ ● ○ ● ○ ● ○ 2A(H)

Over flow of receiving buffer.

 

 

 

 

Occurs when the upper CPU processing is delayed. Check the communication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○ ○ ● ○ ● ○ ● ● 2B(H)

Flame length error

• Occurs because of a media execution cable

 

 

○ ○ ● ○ ● ● ○ ○ 2C(H)

Media error

error or noise from outside.

 

 

 

 

○ ○ ● ● ○ ○ ○ ○ 30(H)

EEPROM error

 

Check the communication cable

 

 

 

Replace the JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

● ○ ● ● ● ● ● ○ BE(H)

BCC error

 

Check the parameter contents

 

 

● ○ ● ● ● ● ● ● BF(H)

Parameter setting error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

● ● ○ ○ ○ ○ ○ ● C1(H) Communication error

Check the communication

 

 

 

 

 

 

 

 

 

 

 

• After converting into octal, the lower two digits

 

 

 

 

 

to

 

 

to

 

 

 

 

 

 

 

represent the slave station number of the current

cable and slave module

 

 

FF(H)

error. (Ex. C1(H) = 301(8) = slave station 01)

 

 

 

You need to select the "output error code for a slave station connection condition" at the master

9

 

station parameter addresses 007750 to 007757(8). If more than one slave station has an error,

 

 

the slave station with the lowest station number will be displayed.

 

 

Remarks

Error codes “23” and “2A(H)” may occur when applying power. This is not an error.

To check the communication cable, remove both connectors and short the connector terminals at one end. Then measure the conductivity using a tester.

Check the parameter and switch settings for all stations. If the settings are correct, replace the JW-20CM or JW-20RS.

9·54