(2)Flag

Flag area is 24 bytes from the “flag top address” set in the master station/slave station parameters.

Flag table [ In case of flag top address is 0740 (initial value) ]

Slave station 01(8)

Master station

0740

0741

0742

0743

0744

0745

0746

0747

0750

0751

0752

0753

0754

0755

0756

0757

0760

0761

0762

0763

0764

0765

0766

0767

07

06

05

04

03

02

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

16

15

14

13

12

11

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

26

25

24

23

22

21

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

36

35

34

33

32

31

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication

 

47

46

45

44

43

42

41

40

 

 

 

 

 

monitor flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

56

55

54

53

52

51

50

 

 

Slave station 70(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

66

65

64

63

62

61

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

76

75

74

73

72

71

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master station

 

07

06

05

04

03

02

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

16

15

14

13

12

11

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

26

25

24

23

22

21

20

 

 

Slave station 01(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

36

35

34

33

32

31

30

 

 

 

 

 

 

 

Operation condition

 

 

 

 

 

 

 

 

 

 

 

 

 

monitor flag [1]

 

47

46

45

44

43

42

41

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slave station 70(8)

9

57

56

55

54

53

52

51

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

66

65

64

63

62

61

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

76

75

74

73

72

71

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Master station

 

07

06

05

04

03

02

01

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

16

15

14

13

12

11

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slave station 01(8)

 

27

26

25

24

23

22

21

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

36

35

34

33

32

31

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation condition

 

 

 

 

 

 

 

 

 

 

47

46

45

44

43

42

41

40

 

 

 

monitor flag [1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

56

55

54

53

52

51

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

67

66

65

64

63

62

61

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slave station 70(8)

 

77

76

75

74

73

72

71

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks

• Even a slave station can monitor 24 bytes of flag.

9·55