7-8 Wiring to power supply module

[1]JW-1PU

·Open the terminal block cover, fasten with the screw with torque of less than 12kg·cm.

·A maximum of three halt output lines can be connected serial. To use more than three sets, use a relay for interconnection.

In case of 100 VAC input

In case of 100 VAC input Terminal block cover

 

SHORT

1

 

200 VAC

2

 

SHORT

 

 

 

100 VAC

3

 

 

 

INPUT

4

100 VAC

 

 

 

or 200 VAC

 

5

 

 

 

GND

6

 

 

 

 

7

halt output

line8

DC relay

The coil rating must conform to the power supply voltage.

Terminal block cover

7

In case of using DC output module, connect the AC relay in the halt output line and insert the

 

contact with the emergency stop circuit.

 

In case of 200 VAC input

·In case of using 200 VAC, switched to the 200 V side in terminal block of power supply module.

·If 200 V is added with the clip connected to the 100 V side, it may damage the power supply module.

In case of 100 VAC input

 

SHORT

1

 

 

 

200 VAC

2

 

 

 

SHORT

7

1A

 

 

 

100 VAC

 

 

3

 

SSR

200 VAC

 

 

 

 

 

 

input

 

4

 

 

 

 

 

 

 

 

5

8

 

 

 

 

 

 

GND

6

Halt output internal circuit

 

 

 

 

 

7·8