(2) F-201

F-201Read from a port

PORT

Symbol

 

F-201

TASKn

PORTn

@ D

 

POR

 

 

 

 

 

 

 

 

 

 

 

Function

Transfer task number "n" and PC memory data (set the top address

using @S) to a ZW/JW-20CM at port "n."

 

 

Operation contents

Contents of @S (Set S to S+6 using the PC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top address for

 

 

 

Resister

 

 

 

D

File address (lower bit)

 

 

sending data

 

n

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+1

 

 

 

(upper bit)

 

 

 

 

 

 

 

n+1

 

 

 

 

 

 

 

D+2

File number

 

 

 

 

 

 

 

 

 

 

n+2

 

 

 

 

 

 

 

D+3

Number of bytes transferred

 

 

 

 

 

 

 

n+3

 

 

 

 

 

 

 

D+4

000(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+5

000(8)

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

000(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+7

Receive station's station number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+10(8)

Completed receiving flag

 

 

 

 

 

 

 

 

7 6

5 4 3 2 1 0

 

 

 

 

D+11(8)

Reserved (not fixed)

 

 

 

 

 

 

 

 

 

 

Not fixed

 

 

 

 

D to D+2: Set the top address for sending data using the file number

 

 

 

 

and file address.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+3: Number of data bytes to transfer from the PC to JW-20CM.

 

 

 

Set to 000 to 255(D). (000(D) equals 256 bytes.)

 

 

 

 

 

 

D+4 to D+6: Reserved area. Set 000(8).

 

 

 

 

 

 

 

 

 

D+7: Station number at which data is sent. Set from ZW/JW-20CM

 

 

 

D+10(8): Station number at which data is sent. Set from ZW/JW-20CM

 

 

 

 

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D+11(8): Reserved area. Status from a port (not fixed). M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range for

Set to TASK 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TASK "n"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range for

Set a port number for the PC basic rack panel on which the ZW/JW-

 

 

PORT "n"

20CM is installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Ex.: JW-13BU)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control module

 

 

 

 

 

 

 

 

JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power module

Port No. ②③④⑤

13·24