(4)Parameter setting of master module (JW-20CM)

Set the following parameter address after setting switch. Setting item varies with using PC (JW model or ZW model).

O:Necessity for setting

 

 

Item

Address

Initial

Setting contents

JW-PC

ZW-PC

See

 

 

value

 

 

 

 

 

 

(8)

Fixed

Manual

Fixed

Manual

page

 

 

 

(H)

 

 

 

 

 

 

 

 

 

 

 

 

001(8): Fixed allocation, asynchronous, error mode 1

 

 

 

 

 

 

 

 

 

 

002(8): Fixed allocation, asynchronous, error mode 2

 

 

 

 

 

 

 

 

 

 

004(8): Fixed allocation, synchronous, error mode 0

 

 

 

 

 

 

 

 

 

 

005(8): Fixed allocation, synchronous, error mode 1

 

 

 

 

 

 

 

Set remote I/O

000000

00

006(8): Fixed allocation, synchronous, error mode 2

8· 34

 

 

operation mode

011(8): Manual allocation, asynchronous, error mode 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

012(8): Manual allocation, asynchronous, error mode 2

 

 

 

 

 

 

 

 

 

 

014(8): Manual allocation, synchronous, error mode 0

 

 

 

 

 

 

 

 

 

 

015(8): Manual allocation, synchronous, error mode 1

 

 

 

 

 

 

 

 

 

 

016(8): Manual allocation, synchronous, error mode 2

 

 

 

 

 

 

 

Set number of

 

 

Set number of connected modules by decimal

 

 

 

 

 

 

 

connected slave

000001

00

8· 35

 

 

notation (01 to 63)

 

 

stations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set remote I/O top

000002

00

Set file address by octal notation

8· 35

 

 

address

000003

 

 

 

 

 

 

 

 

 

 

 

Enter the remote I/O

000004

 

 

 

 

 

 

 

 

 

top address of slave

to

00

Enter the file address by octal notation

8· 40

 

 

station 02 to 77

000177

 

 

 

 

 

 

 

 

 

Enter the number of

 

 

00(H): 64 points (8 bytes), number of slave station; 63

 

 

 

 

 

 

 

000200

00

01(H): 128 points (16 bytes), number of slave station;

8· 38

 

 

slave I/O points

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter the number of

000201

 

Enter the number of bytes of each slave station in

 

 

 

 

 

 

 

I/O bytes for each

to

00

8· 42

 

 

decimal notation (0 to 128)

 

 

slave station

000277

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set blank between

000301

 

Enter the number of blank bytes between stations in

 

 

 

 

 

 

 

to

00

8· 39

 

 

stations

decimal notation (0 to 255)

 

 

000376

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter I/O type for

000400

 

Set each station in bit unit

 

 

 

 

 

8

 

 

 

 

 

 

 

 

to

FF

0: ZW model I/O module

8· 43

 

each slave station

 

 

 

000407

 

1: JW model I/O module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter the data

000600

 

Set using 4 bytes per module

 

 

 

 

 

register address of

to

00

(Set slave station number, rack number, slot number,

8· 44

 

 

 

 

the special I/O mode

000777

 

number of data bytes, and register top address.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Set top address of

003764

 

 

 

 

 

 

 

 

 

to

00

Set file address with octal notation.

8· 36

 

 

flag area

 

 

003767

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00(H) : Stop remote I/O operation

 

 

 

 

 

 

 

Writing to the

 

 

01(H) : Start remote I/O operation

 

 

 

 

 

 

 

EEPROM, start

003777

01

80(H) : Writing to the EEPROM, stop operation

8· 37

 

 

operation/stop setting

 

 

81(H) : Writing to the EEPROM, start operation

 

 

 

 

 

 

 

 

 

 

08(H) : Initialize the parameter

 

 

 

 

 

· If a special I/O module is not set in a slave station, the setting is not required.

8·30