When any of errors “01(H)” to “18(H)” occurs among the error codes listed on the previous page, the JW- 20CM stores error code “53(H)” (optional error) in the system memory #160. It does not store any error code in system memory #170.

In the case of an option error "53," when you monitor system memory #050, the bit of error option module switches ON. When more than 1 bit is error, these bits switch ON. The each ON bit becomes OFF by recovering from the error condition. But the last ON bit does not become OFF even if the error condition recovers.

7

6

5

4

3

2

1

0

#050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 6 error

 

Port 4 error

Port 2 error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 7 error

 

Port 5 error

 

Port 3 error

The option slot port numbers are assigned in the order 2, 3, 4, 5, 6, 7, and so on, starting from the position closet to the control module.