From the previous page
Writing to the EEPROM of the | [HEX (hexadecimal), byte] |
|
|
·Write “81(H)” into parameter address 003777(8) and write the set parameter contents into the EEPROM of the
·After starting operation, the setting value changes to “01(H).”
Setting | Contents |
value (H) | |
0 0(H) | Stop operation of the remote I/O (initial value) |
·Calculate BCC of parameter addresses 000000 to 003775(8).
0 1 When normal, the remote I/O will start operation.
When abnormal, the module will output error code BE(H).
①Check the parameter contents
When normal, the module calculates BCC and writes the check sum
value into address 003776(8).
When abnormal, it outputs a BF(H) error code.
8 0(H) ② Changes the value to 00(H) (stops the operation of the remote I/O), and writes it into the EEPROM.
If a write error to the EEPROM occurs, it outputs a 30(H) error code and keeps the value set to 80(H).
Writing to the EEPROM of the
①Check the parameter contents
When normal, the module calculates BCC and writes the check sum value into address 003776(8).
When abnormal, it outputs a BF(H) error code.
8 1(H) ② Changes the value to 01(H) (starts the operation of the remote I/O), and
writes it into the EEPROM.8 If a write error to the EEPROM occurs, it outputs a 30(H) error code and
keeps the value set to 81(H).
Writing to the EEPROM of the
0 8 Initialize setting values of parameter addresses 000000 to 003777(8)
(Operation example of | Screen display of | ||
| 03775 | HEX | 00 |
| 03776 | HEX | 00 |
Display the contents of address | I PARAM. |
|
|
>03777 | HEX | 01 | |
003777(8) | Write 81(H) |
|
|
|
|
|
PC operation
Turning a master station PC to monitor or change mode (PC operation).
(Operation example of
Monitor mode
Change mode
8·37