Setting range for "S"

PC model name

 

W70H/100H

JW50/70/100, JW50H/70H/100H

 

 

 

 

 

 

 

 

 

 

 

Setting range

 

0000 to 1566

 

0000 to 1566

 

 

 

[ 2]

 

b0000 to b1766

 

b0000 to b1766

 

 

 

 

 

09000 to 09766

 

09000 to 09766

 

 

 

 

 

19000 to 19766

 

29000 to E1766

 

 

 

 

 

 

 

 

 

Operation conditions

· Rising edge of the input signal (OFF to ON) [3]

 

 

 

 

 

 

 

 

 

 

 

Flag

Contents

Non-carry

Error

Carry

Zero

07354

07355

07356

07357

[4]

 

 

 

No ZW/JW-20CM on the option board

0

1

0

0

 

 

 

 

 

 

 

 

 

 

 

Waiting for a data transfer from a ZW/

1

0

0

0

 

 

JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Completed a data transfer from a ZW/

0

0

1

0

 

 

JW-20CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None of the above.

 

0

0

0

0

 

 

 

 

 

 

 

 

 

[ 1] The description for this instruction is for the ZW/JW-20CM only. It is different from the contents in the PC programming manual. The F-201 instruction can only be used for one ZW/JW- 20CM module.

[ 2] Use 0732 to 0737 for special relays.

[ 3] When the F-200 instruction is turned ON, the non carry (07354) will be kept ON until the data transfer to the number 2 port memory is complete. Even if the JW-20CM receives data from an other station using the F-200 instruction, it will remain inside the ZW/JW-20CM until the F-201 input signal changes ON from OFF, and the following data sent by the F-200 instruction will not be received. If the PC power is turned OFF, the data currently being received will be turned OFF.

[ 4] If the JW-20CM receives data using a continuous stream of F-200 instruction, the receive completion flag D+10(8) may not turn OFF. In this case use both the receive completion flag and the carry (07356) when programming.