Self-diagnosis function

Trouble check

Self-diagnosis function

If the self-diagnosis function is activated to prevent the camcorder from operating abnormally, the five digit service number (combination of an alphabet and figures) flashes in the viewfinder or display window. In this case, check the following table.

C:21:00

First three digits

Cause and/or Corrective Action

C21

•Moisture condensation has occurred.

 

mRemove the cassette and leave the camcorder for at least 1

 

hour. (p. 66)

C22

•The video heads are dirty.

 

mClean the heads using the Sony V8-25CLH cleaning cassette

 

(not supplied). (p. 67)

 

 

C23

•The camcorder does not operate when using a battery that is not

 

an InfoLITHIUM battery.

 

mUse an InfoLITHIUM battery. (p. 7)

 

 

C31

•To prevent the camcorder from operating abnormally, the self-

 

diagnosis function has come on.

 

mRemove the cassette and insert it again, and then operate the

 

camcorder. (p. 12)

 

 

C32

•To prevent the camcorder from operating abnormally, the self-

 

diagnosis function has come on.

 

mDisconnect the mains lead of the AC power adaptor or remove

 

the battery pack. After reconnecting or reattaching the power

 

source, operate the camcorder.

 

 

E61

•To prevent the camcorder from operating abnormally, the self-

E62

diagnosis function has come on.

 

mWhen you contact your local authorized Sony service facility,

 

inform the service number with five digits. (example: E:61:10)

If a difficulty persists after checking the problem a few times, contact your local authorized Sony service facility.