Inspect air cleaner filter element every 100 hours of op- eration. Replace every 400 hours or when dirty or dam- aged

1.Check air cleaner body and body for damage that could cause possible air leaks. Replace damaged air cleaner body or cover (see Remote Air Cleaner Remov- al and Installation).

2.Release latches securing air cleaner cover to air cleaner body. Separate cover from the body. Clean in- side of the air cleaner cover.

3.Wash filter element with soap and water as follows:

A.Prepare a solution of filter cleaner and water. Soak filter element about 15 minutes. See filter cleaner carton for detailed instructions.

B.After soaking filter for 15 minutes, rinse it with clear water. Maximum water pressure must not ex- ceed 40 psi to prevent damage to the filter element. Rinse filter element from clean side to dirty to side.

C.Dry filter element using warm, flowing air not ex- ceeding 160_F, or allow element to air–dry. Do not use a light bulb to dry the filter element because damage may result.

CAUTION

Use eye protection such as goggles when using compressed air.

4.Clean filter element with compressed air as follows:

A.Blow compressed air from the inside to the out- side of the dry filter element. Do not exceed 100 psi to prevent damage to the element.

B.Keep air hose nozzle at least 2 inches from the filter. Move nozzle up and down while rotating the fil- ter element. Inspect for holes and tears by looking through the filter toward a bright light.

5.Inspect new filter element for shipping damage. Check sealing end of element. Do not install a damaged filter element.

6.Insert new filter element properly into the air cleaner body. Make sure element is sealed properly by applying pressure to outer rim of filter when installing. Do not press on flexible center of filter.

7.Reinstall cover and secure latches. Make sure cov- er is positioned with TOP side up.

1

2

3

4

Figure 8

1.

Latch

3.

Body

2.

Cover

4.

Filter element

4

1

 

 

 

3

 

 

2

 

 

 

Figure 9

 

1.

Latch

3.

Body

2.

Cover

4.

Air inlet hood

Engine

Sand Pro 2020/3020/5020

Page 3 – 9

Engine

Page 29
Image 29
Toro 3020, 5020 Service Remote Air Cleaner, Use eye protection such as goggles when using compressed air, Engine, Page 3