e-STUDIO3511/4511 POWER SUPPLY UNIT 7 - 4 November 2003 © TOSHIBA TEC

7.3 Configuration of Power Supply Unit
IH
F1
F2
Reg.
Reg.
+24VD1 CN470 Power supply cooling fan
+24VD4 CN467 SLG board, SDV board
+5.1VD CN466 LGC board
+3.3VA CN464 SYS board
+5.1VA CN464 SYS board
+12VB CN466 LGC board
+12VA CN464 SYS board
+24VD5 CN468 Finisher
+24VD3 CN467 RADF
+12VB CN464 SYS board
+24VD2 CN465 DRV board
+3.3VB CN464 SYS board
+3.3VB CN466 LGC board
+3.3VB CN467 SLG board
+5.1VB CN464 SYS board
+5.1VB CN466 LGC board, CCL board (via LGC board),
PFP/LCF (via LGC board),
Bridge unit (via LGC board)
+5.1VB CN467 SLG board, RADF
+5.1VB CN468 Finisher
+5.1VB CN469 FIL board or FUS board
+24VD1 CN465 LGC board, CCL board (via LGC board),
Bridge unit (via LGC board)
+24VD1 CN469 PFP/LCF
-12VA CN464 SYS board
AC MAIN
AC DOOR
AC IN
CN460
CN460
Live
Main switch Door switch
Switching
power supply
Noise
filter
Noise
filter
Noise
filter
Neutral
Breaker
-12VB CN464 SYS board
F5
F7
F4
F3
F6
FIL board
FUS board
*ASD/AUD/CND models: Standard
*MJD model: Option
*NAD/SAD/TWD models: Standard
ICP1