15. SET UP MODE |
15.3 Bar Code Format Setting
NOTES:
1.Setting error condition
(1)Irregular data pattern of Price Except the following pattern
a)P1 P2 P3 P4
b)P1 P2 P3 P4 P5
c)P1 P2 P3 P4 P5 P6
d)P1 P2 P3 P4 P5 P6 P7
Price data should be continuous setting.
(2)Irregular data pattern of weight Except the following pattern
a)W1 W2 W3 W4
b)W1 W2 W3 W4 W5
Weight data should be continuous setting.
(3)Irregular calculation pattern of PC/D. Except the following pattern
a)P1 P2 P3 P4
b)P1 P2 P3 P4 P5
c)W1 W2 W3 W4
d)W1 W2 W3 W4 W5
Error occurred when PC/D can not calculate.
(4)It is error that same data is found in a barcode format. Regarding following.
a)W1 – W5
b)P1 – P7
c)PC/D
2.Data error condition
It will be printed only code data (C1 – C6) if error occurred.
(1)Irregular Price
Price pattern |
| Barcode format pattern |
| ||
P1234 | P12345 | P123456 | P1234567 | ||
| |||||
$0.01 | 0001 | 00001 | 000001 | 0000001 | |
$0.12 | 0012 | 00012 | 000012 | 0000012 | |
$1.23 | 0123 | 00123 | 000123 | 0000123 | |
$12.34 | 1234 | 01234 | 001234 | 0001234 | |
$123.45 | Error | 12345 | 012345 | 0012345 | |
$1234.56 | Error | Error | 123456 | 0123456 | |
$12345.67 | Error | Error | Error | 1234567 |
(2) Irregular Weight
Weight pattern | Format pattern | ||
W1234 | W12345 | ||
| |||
0.005lb | 0005 | 00005 | |
0.015lb | 0015 | 00015 | |
0.125lb | 0125 | 00125 | |
1.235lb | 1235 | 01235 | |
12.345lb | Error | 12345 | |
15.34lb | Error | 15340 |