16. REGISTRATION MODE |
16.2 Basic Operations
6.Place a commodity on the platter. A label is issued (AUTO) or touch the [PRT/*] key (MANUAL).
NOTE: With the initial settings, a %tare cannot be preset to a PLU. Therefore, even if a %tare is set to a PLU, the data will become invalid. When you desire to use this function, contact the nearest TOSHIBA TEC service representative or sales agent.
16.2.5 Void
In case of an erroneous entry, etc., you can delete the data just after it has been registered.
1.Place a commodity on the platter. A label is issued.
2.Touch the [VOID] key to delete this data. The data is deleted and “VOID EXECUTION” is displayed.
VOID key
NOTE: The void operation is effective only after the data has been just entered. Calling another PLU or exiting from the REGISTRATION Mode disables the void operation.
16.2.6 Vendor Log-in
NOTE: This operation is also available in the Fix, By count, and Net Weight Statement operations.
1.First, change the label issue method to the MANUAL. (See Section 16.1.3) In the AUTO mode, the vendor cannot be registered.
2.Enter the tare. (This is not necessary when the tare has been preset to the PLU.)
3.Call the PLU.
4.Enter the unit price and tare. (This is not necessary when they have been set to the PLU.)
5.Place a commodity on the platter.