14. PROGRAMMING MODE

EO1-31009

 

14.2 PLU Data Setting

 

 

 

 

 

 

Item

Procedure

 

 

 

 

Tare,

Input a numeric data (max. 2lb for lb scale, 1kg for kg scale, or 99.9%

 

%Tare

for %Tare).

 

 

NOTES:

 

 

1. With the initial settings, Preset tare and %Tare function is not available.

 

 

When these functions are required, contact the nearest TOSHIBA TEC

 

 

service representative or sales agent.

 

 

2. %Tare data exceeding the tare limit results in an error.

 

 

3. When the NET statement labels are to be issued, enter the net weight (0 –

 

 

480 oz) to the PLU tare area.

 

 

 

 

Tare Limit

1. Input a numeric data in the following range:

 

 

Lb scale: 0.000 – 2.000lb (Default: 2.000lb)

 

 

Kg scale: 0.000kg – 1.000kg (Default: 1.000kg)

 

 

2. Touch the Tare Limit area.

 

 

3. The confirmation screen will appear.

 

 

4. Touch the [Go] key to enter the data. To cancel, touch the [Cancel]

 

 

key.

 

 

NOTES:

 

 

1. With the initial settings, this function is not available. When this function is

 

 

required, contact the nearest TOSHIBA TEC service representative or sales

 

 

agent.

 

 

2. If the actual tare exceeds the tare limit, an error occurs.

 

 

 

 

Compulsory tare

Select YES or NO.

 

subtraction

YES: Tare subtraction is compulsory.

 

 

NO: Tare subtraction is not compulsory.

 

 

NOTE: With the initial settings, YES cannot be selected. When this function

 

 

is required, contact the nearest TOSHIBA TEC service representative or

 

 

sales agent.

 

 

 

 

14- 7