| 14. PROGRAMMING MODE |
| ||
|
|
| 14.19 DLL (LAN Master/Satellite System) Setting | |
|
|
|
|
|
| Procedure |
|
|
|
| Item |
| Procedure |
|
| Setting to OFF Line | 1. | Touch the [OFF LINE] key. |
|
|
| 2. | Touch the [BACK] key. |
|
|
| 3. | Turn the power off and then on again according to the message. |
|
| Designating the scale to a | 1. | Touch the [MASTER] key. |
|
| master and setting the IP | 2. | Touch the [BACK] key twice. |
|
| address | 3. | Turn the power off and then on again according to the message. |
|
|
| NOTE: When the scale is designated to a master, its IP address will |
| |
|
| appear as ID01 (MASTER ID) automatically. Also, all of the satellites IP |
| |
|
| addresses are automatically displayed. |
| |
| Designating the scale to a | 1. | Touch the [SATELLITE] key. |
|
| satellite and setting the IP | 2. | Input the IP address of the master scale. |
|
| address | 3. | Touch the IP address area (ID No. 1). |
|
|
| 4. | Touch the [BACK] key twice. |
|
|
| 5. | Turn the power off and then on again according to the message. |
|
|
| NOTE: When the scale is designated to a satellite, set the master |
| |
|
| scale’s IP address only. |
|
14.19 DLL (LAN Master/Satellite System) Setting
When the scale is designated to the master, you can download the data to the satellite using the LAN. (Refer to Section 14.18.)
The following screen will appear when the [DLL (LAN)] key of the Programming Mode Main Menu is touched. Select the item to be downloaded and destination satellite.
ALL key | OPEN key |
CLOSE key
Item key
ALL SATELLITES key
CANCEL key
Scale ID# key ID02
DISCONNECT key
DLL key