Appendixes
Front Panel Controls
3UHVV | /&' | 'HVFULSWLRQ |
|
|
|
Setting the Applicator Port: Press the right or left black oval to display other choices.
Default: Off
Selections: Off, mode 1, mode 2, mode 3, mode 4
$33/,&$725 Determines the action of the verifier port. 3257
Off: The applicator port is off.
Mode 1: Asserts the ~END_PRINT signal low while the printer is moving the label forward.
Mode 2: Asserts the ~END_PRINT signal high while the printer is moving the label forward.
Mode 3: Asserts the ~END_PRINT signal low for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes.
Mode 4: Asserts the ~END_PRINT signal high for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes.
Note • Set as suggested by the applicator manufacturer.