Appendixes
Specifications and Care
7RFOHDQWKHSULQWKHDGFRPSOHWHWKHVHVWHSV
1.Open the printhead.
2.Remove the labels and ribbon (if loaded).
3.Moisten an applicator tip with solvent and wipe along the print elements from end to end. (The print elements are on the brown strip just behind the chrome strip on the printhead.)
Allow a few seconds for the solvent to evaporate.
4.Rotate the platen roller and clean thoroughly with solvent and an applicator.
5.Brush or vacuum any accumulated paper lint and dust away from the rollers.
6.Reload ribbon and close the printhead.
Note • If print quality has not improved after performing this procedure, try cleaning the printhead with
6HQVRUV
Brush or vacuum any accumulated paper lint and dust off the sensors at any time the sensors are blocked. At minimum, clean the sensors (the ribbon sensor and optional label available sensor shown below and the media sensors shown in Sensor Adjustment on page 20) according to the schedule in Routine Procedures on page 112.
The callouts in this illustration show the sensor components and the printhead and platen roller assembly. The table that follows identifies the callouts.
114 | Zebra XiIIIPlus Users Guide |