Data Ports
Standard Ports
56,QWHUIDFH&RQQHFWLRQV
Note • Adapters are available from Zebra Technologies LLC. ‡RS422/RS485 adapter, Zebra part number 33130 ‡RS232 DB9 to DB 25 adapter, Zebra part number 33138
'LUHFWFRQQHFWLRQWRDFRPSXWHU
The printer is configured as Data Terminal Equipment (DTE).
Note • The cable used to connect the printer to a computer must be a null modem (crossover) cable. To connect the printer to any other DTE devices, use a null modem cable.
This illustration shows the internal connections of the printer’s
RS-232 Connector (DTE)
Rear Panel Female DB-9
+5 VDC
R1
1 K
2
3
4
5
6
7
8
9
RXD (receive data) input
TXD (transmit data) output
DTR (data terminal ready) output
SG (signal ground)
DSR (data set ready) input
RTS (request to send) output
CTS (clear to send) input
+5 VDC signal source
NOTE: Pin 1 is unused and unterminated.
Note • Pin 9 is also available as a +5 VDC power source at 750 mA. The maximum current draw may be limited by option configuration. To enable this capability, a jumper on the computer’s main logic board needs to be installed on JP1, pins 2 and 3