)XVH￿5HSODFHPHQW￿

￿￿;L,,,3OXV￿￿￿￿;L,,,3OXV￿￿￿￿￿;L,,,3OXV￿￿￿￿￿;L,,,3OXV￿￿DQG￿

￿￿￿;L,,,3OXV

!Important • The 110XiIIIPlus fuse can be replaced only by an authorized service technician.

Caution • Turn the AC power switch Off (O) and remove the power cord before performing this procedure.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry module comes with two approved fuses in the fuse holder: one is in- circuit and the second is provided as a spare (see the Fuse Removal illustration below). The end caps of the fuse must bear the certification mark of a known international safety organization.

7R￿UHSODFH￿D￿IDXOW\￿IXVH￿￿FRPSOHWH￿WKHVH￿VWHSV￿

1.Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer. The illustration callouts and the table that follows identify the parts of the AC power entry modlule.

 

2

1

3

 

 

4

&DOORXW 'HVFULSWLRQ

￿Fuse holder

￿Power switch