Printer Setup and Calibration

Before You Begin

7R￿DGMXVW￿WKH￿XSSHU￿DQG￿ORZHU￿PHGLD￿VHQVRUV￿￿FRPSOHWH￿WKHVH￿

VWHSV￿

1.Remove the ribbon (if ribbon is used).

2.Locate the upper media sensor. The upper media sensor eye is directly below the adjustment screw head.

See the illustration for a simplified view of the media sensor. Callouts in the illustration are explained in the table that follows.

 

1

 

2

&DOORXW

'HVFULSWLRQ

￿Upper media sensor adjustment screw

￿Upper media sensor

Note • If you are using continuous media, position the upper media sensor over the labels so that the printer can detect an out-of-paper condition.

3.Slightly loosen the upper media sensor adjustment screw (use a Phillips-head screwdriver).

4.Using the tip of the screwdriver, slide the upper sensor along the slot to the desired position.

5.Tighten the adjustment screw to secure the upper media sensor.