Zebra Technologies 3ULQWHUV manual This procedure is used to adjust the sensitivity

Models: 3ULQWHUV

1 168
Download 168 pages 13.74 Kb
Page 90
Image 90

Appendixes

Front Panel Controls

3UHVV

/&'

'HVFULSWLRQ

 

 

 

 

 

This procedure is used to adjust the sensitivity of the

 

0(',$￿$1'￿

media and ribbon sensors.

 

 

 

 

5,%%21￿

Note • The procedure must be followed exactly as

 

&$/,%5$7(

 

 

presented. All steps must be performed even if only

 

 

one of the sensors requires adjustment.

 

 

1.

Press NEXT/SAVE to skip the calibration

 

 

 

procedure and continue with the host port

 

 

 

selection parameters that follow.

 

 

2.

Press the right black oval to start the calibration

 

 

 

procedure.

 

 

Note • You may press the left black oval at any step

 

 

in this procedure to cancel the procedure.

 

 

 

 

 

 

1.

Open the printhead.

 

 

2.

Remove approximately 8 in. (203 mm) of labels

 

/2$'￿%$&.,1*

 

from the media liner, and pull the media into the

 

 

 

printer so that only the liner is between the media

 

 

 

sensors.

 

 

3.

Leave the printhead open.

 

 

4.

Press the right black oval to continue.

 

 

 

 

 

 

1.

Press the left black oval to cancel the operation or

 

5(029(￿

 

do the following:

 

 

 

 

5,%%21

2. Remove the ribbon.

 

 

3.

Close the printhead.

 

 

4.

Press the right black oval to continue.

 

 

 

 

 

The printer automatically adjusts the scale (gain) of

 

&$/,%5$7,1*

the signals it receives from the media and ribbon

 

3/($6(￿:$,7

sensors. On the sensor profile, this essentially

 

 

corresponds to moving the peak of the graph up or

 

 

down to optimize the readings for your application.

 

 

 

 

70

Zebra XiIIIPlus Users Guide

Page 90
Image 90
Zebra Technologies 3ULQWHUV manual This procedure is used to adjust the sensitivity