Appendixes

Troubleshooting

3$86(￿6HOI￿7HVW

This self test can be used to provide the test labels required when making adjustments to the printer’s mechanical assemblies. See the sample printout below.

7R￿SHUIRUP￿D￿3$86(￿VHOI￿WHVW￿￿FRPSOHWH￿WKHVH￿VWHSV￿

1.Turn off the printer.

2.Press and hold PAUSE while turning the power On (I). Hold PAUSE until the Data light turns off.

The initial self test prints 15 labels at 2.4 in. (61 mm) per second (1 in. or 25.4 mm per second for the 96XiIIIPlus), then automatically pauses the printer. When PAUSE is pressed, an additional 15 labels print. The labels are like the one shown below.

While the printer is paused, pressing CANCEL alters the self test. When PAUSE is pressed, 15 labels print at 6 in. or 152 mm per second (4 in. or 102 mm per second for the 96XiIIIPlus).

While the printer is paused, pressing CANCEL again alters the self test a second time. When PAUSE is pressed, 50 labels print at 2.4 in. (61 mm per second). For the 96XiIIIPlus, printing at 1 in. (25.4 mm) per second.

While the printer is paused, pressing CANCEL again alters the self test a

third time. When PAUSE is pressed, 50 labels print at 6 in. (152 mm) per second. For the 96XiIIIPlus, printing at 4 in. (102 mm) per second .

While the printer is paused, pressing CANCEL again alters the self test a fourth time. When PAUSE is pressed, 15 labels print at the printer’s maximum speed.

To exit this self test at any time, press and hold CANCEL.

134

Zebra XiIIIPlus Users Guide

Page 154
Image 154
Zebra Technologies 3ULQWHUV manual $866HOI7HVW, 7RSHUIRUPD3$86VHOIWHVWFRPSOHWHWKHVHVWHSV