Command Reference | Change Password Incoming |
2.42 Change Password Incoming
DISABLED
CHANGE PORT PortList PASSWORD INCOMING ENABLED
Controls whether the MSS will ask users for an incoming password when they attempt to connect to the network socket connection ports (ports 200x and 300x, where x is the number of the desired serial port). See Environment Strings on page
Restrictions | Requires privileged user status |
ParametersPort
MSS4 only. Specifies a particular port or group of ports.
Note: In the absence of the PortList parameter, the configuration will affect the MSS4’s current port only.
PortList
Specify a particular port or group of ports. Port numbers are specified with integers between 1 and 4, and should be separated with commas (for lists) or dashes (for ranges).
2.43 Change Password Limit
CHANGE [ SERVER] PASSWORD LIMIT number
Limits the number of failures allowed when entering the privileged password, with the Set Privileged command, to become the privileged user. After the specified number of retries, the port will be logged out. The Change Privpass command is used to set the privileged password.
Restrictions | Requires privileged user status. |
Parameters | Server |
| MSS4 only. |
| number |
| Enter a value between 0 (no limit) and 100. |
Defaults | 3 |