Chapter 13: AI2524 Frame Relay Configuration Steps
August 1997 Page 13-9
2524UM
3. Enable Frame Relay encapsulation on the interface.
encapsulation frame-relay
4. Assign a map group to the interface.
map-group
group-name
5. Enable Frame Relay SVC support on the interface.
frame-relay svc
Map-group details are specified with the map-list command.
Example: SVCs on an Interface
This example configures a physical interface, applies a map-group to
the physical interface, and then defines the map-group.
interface serial 0
ip address 172.10.8.6
encapsulation frame-relay
map-group bermuda
frame-relay lmi-type q933a
frame-relay svc
map-list bermuda source-addr E164 123456 dest-addr E1 64 6 54321
ip 131.108.177.100 class hawaii
appletalk 1000.2 class rainbow
map-class frame-relay rainbow
frame-relay idle-timer 60
map-class frame-relay hawaii
frame-relay cir in 64000
frame-relay cir out 64000
Configure SVCs on a Subinterface (optional)
To configure Frame Relay SVCs on a subinterface, perform all th
tasks in the previous section, except assigning a map grou p . Then, be-
ginning in global configuration mode, complete these tasks:
1. Specify a subinterface of the main interface configured for SVC
operation.
interface serial

number.subinterface-

number
{multipoint | point-to-point}