Chapter 14: T1 Interface Configuration Steps
August 1997 Page 14-1
2524UM
Chapter 14: T1 Interface Configuration
Steps
Introduction This chapter describes how to configure the AI2524 for fractional T1.

Configure

Fractional T1 Configuration Overview
This section describes how to configure fractional T1 and T1 (FT1/T1
service modules installed the AI242 5 route r. The t asks associa ted with
configuring T1 include:
zSpecify the Clock Source
zEnable Data Inversion Before Transmission
zSpecify the Frame Type of a FT/T1 Line
zSpecify the CSU Line Build Out
zSpecify FT1/T1 Line-Code Type
zEnable Remote Alarms
zEnable Loopcodes that Initiate Remote Loopbacks
zSpecify Timeslots

Specify the Clock Source

To specify the clock source for the FT1/T1 CSU/DSU internal clock
or the line clock, type this in interface configuration mode:
service-module t1 clock source {internal |
line}

Enable Data Inversion Before Transmission

Data inversion is used to guarantee the T1s density requirement on an
AMI line when using bit-oriented protocols such as High-Level Data
Link Control (HDLC), Point-to-Point Protocol (PPP), X.25, and
Frame Relay.